4WRZ32W8-360-70/6EG24N9TK4/D3M
4WRZ32W8-360-70/6EG24N9ETK4/M
4WRZ32W8-360-70/6EG24N9K4/M Original genuine proportional German
made Rexroth hydraulic electro-hydraulic proportional directional
valve
| Selection Dimension | Specific Parameters/Options | Description |
| Model Designation | 4WRE | Basic model: Direct-acting proportional directional valve with electrical position feedback and no integrated electronics (OBE) |
| Integrated Electronics (OBE) | No Code | Standard configuration without integrated electronics; external amplifier required (to be ordered separately) |
| Nominal Size | 6 | Core size with component series 2X; mounting dimensions comply with Series 20-29 standards |
| Valve Core Type | 4/2 (2-position 4-way), 4/3 (3-position 4-way) | 4/3 type features spring-centered spool for automatic reset when de-energized; suitable for different oil circuit directional control needs |
| Rated Flow (Δp=10bar) | 4L/min (Code 04), 8L/min (Code 08), 16L/min (Code 16), 32L/min (Code 32) | Flow rates distinguished by corresponding codes; matched to hydraulic system flow requirements |
| Seal Material | V (FKM Fluororubber) | Default FKM material; compatible with mineral oil and other hydraulic fluids to ensure sealing performance |
| Power Supply Voltage | G24 (DC 24V) | Suitable for industrial standard DC power supply; meets proportional solenoid drive requirements |
| Electrical Interface | A1 (±10V Voltage Input), F1 (4-20mA Current Input) | Two interface options available; compatible with PLCs, computers, and other control signal sources |
| Electrical Connection | K4 (No Plug) | Plug compliant with DIN EN 175301-803 standard required (to be ordered separately) |
| Special Protection | J (Seawater-Resistant) | Only available for Size 6; suitable for marine-related or humid/corrosive working conditions |
| Mounting Standard | ISO 4401 | Panel mounting with standard mounting hole pattern; compatible with universal hydraulic system manifold layouts |
| Maximum Working Pressure | 315bar | Suitable for most medium-to-high pressure industrial hydraulic scenarios (e.g., hydraulic actuators in machine tools, automated production lines) |

| 4WRZ16E150-7X/6EG24N9EK4/M |
| 4WRZ16E1-100-7X/6EG24N9EK4/D3M |
| 4WRZ16E1-100-7X/6EG24N9EK4/M |
| 4WRZ16E1-100-7X/6EG24N9K4/D3M |
| 4WRZ16E1-100-7X/6EG24N9K4/M |
| 4WRZ16E180-7X/6EG24N9EK4/M |
| 4WRZ16E180-7X/6EG24N9K4/D3M |
| 4WRZ16E180-7X/6EG24N9K4/M |
| 4WRZ16E150-7X/6EG24N9TK4/D3M |
| 4WRZ16E150-7X/6EG24N9TK4/M |
| 4WRZ16E150-7X/6EG24N9ETK4/D3M |
| 4WRZ16E150-7X/6EG24N9ETK4/M |
| 4WRZ16E150-7X/6EG24N9EK4/D3M |
| 4WRZ16E150-7X/6EG24N9K4/D3M |
| 4WRZ16E125-7X/6EG24N9EK4/M |
| 4WRZ16E125-7X/6EG24N9K4/D3M |
| 4WRZ16E125-7X/6EG24N9K4/M |
| 4WRZ16E100-7X/6EG24N9TK4/D3M |
| 4WRZ16E100-7X/6EG24N9TK4/M |
| 4WRZ16E100-7X/6EG24N9ETK4/D3M |
| 4WRZ16E100-7X/6EG24N9ETK4/M |
| 4WRZ16E100-7X/6EG24N9EK4/D3M |
| 4WRZ16E100-7X/6EG24N9EK4/M |
| 4WRZ16E1-100-7X/6EG24N9ETK4/M |
| 4WRZ16E100-7X/6EG24N9K4/M |
| 4WRZ16E100-7X/6EG24N9K4/D3M |
| 4WRZ32W6A520-70/6EG24N9ETK4/M |
| 4WRZ32EA520-70/6EG24N9ETK4/M |
| 4WRZ32W6-520-70/6EG24N9TK4/D3M |
| 4WRZ32EA360-70/6EG24N9EK4/M |
| 4WRZ32W9-520-70/6EG24N9ETK4/M |
| 4WRZ32W9-520-70/6EG24N9K4/M |
| 4WRZ32W9-360-70/6EG24N9TK4/D3M |
| 4WRZ32W9-360-70/6EG24N9ETK4/M |
| 4WRZ32W9-360-70/6EG24N9K4/M |
| 4WRZ32W8-520-70/6EG24N9TK4/D3M |
| 4WRZ32W8-520-70/6EG24N9ETK4/M |
| 4WRZ32W8-520-70/6EG24N9K4/M |
| 4WRZ32W8-360-70/6EG24N9TK4/D3M |
| 4WRZ32W8-360-70/6EG24N9ETK4/M |
| 4WRZ32W8-360-70/6EG24N9K4/M |
| 4WRZ32W6-520-70/6EG24N9TK4/M |
| 4WRZ32W6-520-70/6EG24N9ETK4/D3M |
| 4WRZ32W6-520-70/6EG24N9ETK4/M |
| 4WRZ32W6-520-70/6EG24N9EK4/D3M |
| 4WRZ32W6-520-70/6EG24N9EK4/M |
| 4WRZ32W6A360-70/6EG24N9K4/M |
| 4WRZ32E1-520-70/6EG24N9TK4/M |
| 4WRZ32W6-520-70/6EG24N9K4/D3M |
| 4WRZ32W6-520-70/6EG24N9K4/M |
| 4WRZ32W6-360-70/6EG24N9TK4/D3M |
| 4WRZ32W6-360-70/6EG24N9TK4/M |
| 4WRZ32W6-360-70/6EG24N9ETK4/D3M |
| 4WRZ32E3-360-70/6EG24N9EK4/M |
| 4WRZ32E3-360-70/6EG24N9K4/D3M |
| 4WRZ32E3-360-70/6EG24N9K4/M |
| 4WRZ32E1-520-70/6EG24N9TK4/D3M |
| 4WRZ32E1-360-70/6EG24N9TK4/M |
| 4WRZ32E520-70/6EG24N9TK4/D3M |
| 4WRZ32E1-520-70/6EG24N9ETK4/M |
| 4WRZ32E1-520-70/6EG24N9EK4/D3M |
| 4WRZ32E1-520-70/6EG24N9EK4/M |
| 4WRZ32E1-520-70/6EG24N9K4/D3M |
| 4WRZ32E1-520-70/6EG24N9K4/M |
| 4WRZ32E1-360-70/6EG24N9TK4/D3M |
| 4WRZ32E1-360-70/6EG24N9ETK4/D3M |
| 4WRZ32E1-360-70/6EG24N9ETK4/M |
| 4WRZ32E1-360-70/6EG24N9EK4/D3M |
| 4WRZ32E1-360-70/6EG24N9EK4/M |
| 4WRZ32E1-360-70/6EG24N9K4/D3M |
| 4WRZ32E1-360-70/6EG24N9K4/M |
| 4WRZ32E520-70/6EG24N9TK4/M |
| 4WRZ32E360-70/6EG24N9K4/M |
| 4WRZ32E520-70/6EG24N9ETK4/D3M |
| 4WRZ32E520-70/6EG24N9ETK4/M |
| 4WRZ32E520-70/6EG24N9EK4/D3M |
| 4WRZ32E520-70/6EG24N9EK4/M |
| 4WRZ32E520-70/6EG24N9K4/D3M |
| 4WRZ32E520-70/6EG24N9K4/M |
| 4WRZ32E360-70/6EG24N9TK4/D3M |
| 4WRZ32E360-70/6EG24N9TK4/M |
| 4WRZ32E360-70/6EG24N9ETK4/D3M |
| 4WRZ32E360-70/6EG24N9ETK4/M |
| 4WRZ32E360-70/6EG24N9EK4/D3M |
| 4WRZ32E360-70/6EG24N9EK4/M |
| 4WRZ32E360-70/6EG24N9K4/D3M |
| 4WRZ32E1-520-70/6EG24N9ETK4/D3M |
| 4WRZ32W8-520-7X/6EG24N9K4/M |
| 4WRZ32W8-360-7X/6EG24N9ETK4/M |
| 4WRZ32W6A360-7X/6EG24N9K4/M |
| 4WRZ32EA520-7X/6EG24N9ETK4/M |
| 4WRZ32EA360-7X/6EG24N9ETK4/M |
| 4WRZ32W9-520-7X/6EG24N9TK4/D3M |
| 4WRZ32W9-520-7X/6EG24N9ETK4/M |
| 4WRZ32W9-520-7X/6EG24N9K4/M |
| 4WRZ32W9-360-7X/6EG24N9TK4/D3M |
| 4WRZ32W9-360-7X/6EG24N9ETK4/M |
| 4WRZ32W9-360-7X/6EG24N9K4/M |
FAQ:
1. What checks are required after commissioning?
Verify flow direction, proportional response to input signals,
spool position indicator functionality (if equipped), and absence
of leaks .
2. How to set up external pilot oil return?
Connect port Y to the tank for external pilot oil return; ensure
return line pressure does not exceed 30 bar .
3. Can 4WRZ valves be mounted in a vertical orientation?
Yes, but horizontal mounting is preferred to minimize wear and
ensure consistent performance .
4. What is the correct order to connect hydraulic lines?
Connect pressure port (P) first, then return port (T), followed by
working ports (A/B); bleed air from lines before energizing the
valve .
5. How to test the spool position indicator?
Apply a gradual electrical input signal; the indicator should
switch outputs when preset spool positions are exceeded (within the
overlap range) .
6. What tools are required for 4WRZ installation?
Torque wrench (for mounting bolts), cable crimping tools (for
electrical connections), and alignment pins (for subplate mounting)
.
|